<ruby id="qe9la"><font id="qe9la"></font></ruby>

      国产精品女丝袜白丝袜,超碰人人澡,在线观看热码亚洲av每日更新,欧美日韩国产亚洲一区二区 ,国产中文天堂在线观看,亚洲国产一线二线三线,国产女人喷潮视频免费,av色天堂
      Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
      Position首頁 > Home > Industrial Safety Products > Safety Controller > Programmable safety controller
      SC-4 security expansion module
      SM-602 programmable safety controller

      As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

      (1) Redundancy

      (2) Difference

      (3) Self-detection


         How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.

      SC-4 security expansion module

      841056c.png

      · Is a safety relay output expansion module.

      · Receive the on-site safety switch signal, and expand it into 4 NO (normally open) safety output contacts and 2 NC (normally closed) auxiliary output contacts. 
      · Two auxiliary contacts can be used for output status indication and fault feedback respectively.

      Product selection     0523ce09f27183840accf49d6c9b5a4.png

      product name

      model

      Safety input

      Safe output

      order number

      SC-4

      24V DC

      Safety switch, contact switch

      4NO+2NC

      LHS
      explain

      Safety switch, contact switch


      safety performance

      ·Performance level (PL): PLE

      ·Safety category (cat.): cat.4.

      ·Task time (TM): 20 years.

      ·Diagnostic coverage (DC/DC AVG): 99%

      ·Safety integrity level (SIL): SIL3

      ·Hardware fault margin (HFT): 1

      ·Safety Failure Score (SFF): 99%

      ·PFHD: 1.78e-9/h

      ·Stop category: 0           

      Comply with the standard EN ISO13849

      Comply with the standard EN ISO13849

      Comply with the standard EN ISO13849

      Comply with the standard EN ISO13849

      Comply with standards IEC61508, IEC62061.

      Comply with standards IEC61508, IEC62061.

      Comply with standards IEC61508, IEC62061.

      Comply with standards IEC61508, IEC62061.

      Comply with standard EN 60204-1.


      Main technical parameters

      Power supply characteristics

      ·Power supply voltage: 24VDC

      ·Voltage range: -15%~+10%

      ·Current loss: ≤70mA(24VDC)

      Input characteristics

      ·Input current: ≤70mA(24VDC)

      ·Conductor resistance: ≤15Ω

      ·Input equipment: safety switch, contact switch.

      output characteristic

      ·Number of contacts: 4NO+2NC

             Safety outputs: 13, 14, 23, 24, 33, 34, 43, 44.

             Auxiliary outputs: 11, 12 (status)

             Y1, Y2 (feedback)

      ·Contact material: AgSnO2+0.2 μm Au.

      ·Contact type: forced guidance

      ·Contact fuse protection: 10A gL/gG, NEOZED (normally open contact)

             6A gL/gG, NEOZED (normally closed contact)

      ·Switching capacity (en 60947-5-1): AC-15, 5a/230v; DC-13, 5A/24V

      ·Mechanical life: more than 107 times

      Time characteristic

      ·Suction buffer time: ≤30ms

      ·Release buffer time: ≤20ms

      ·Recovery time: ≤1000ms

      ·Short interruption of power supply: 20ms


      Environmental characteristic parameters

      ·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

      ·Vibration frequency: 10Hz~55Hz

      ·Vibration amplitude: 0.35mm

      ·Operating temperature: -20℃~+60℃

      ·Storage temperature: -40℃~+85℃

      ·Relative humidity: 10%~90%

      ·Electrical clearance and creepage distance: in accordance with EN60947-1.

      ·Overvoltage grade: Ⅲ

      ·Pollution level: 2

      ·Altitude: ≤2000m

      ·Rated isolation voltage: 250VAC.

      ·Rated impulse voltage: 6000V(1.2/50us)

      ·Insulation strength: 1500VAC for 1min.

      841056c.png


      Functional application parameters

      functional block diagram

      Typical application

      圖片2.png

      典型應用圖.png


      Overall dimensions (depth× height× width):

      Overall dimensions (depth× height× width):114.5mm×99.0mm×22.5mm

      Net weight of product200g

      外形尺寸圖.png


      Wiring diagram

      Power supply/input loop

      Switch input

      電路圖1.png

      Output loop

      電路圖2.png

      feedback loop

      電路圖3.png


      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

      Online service

      Online message

    1. Click to refresh
    2. 主站蜘蛛池模板: 被c到高潮疯狂喷水国产 | 亚洲亚洲人成综合网络| 国产精品爱久久久久久久电影 | 亚洲精品无码久久久久sm| 东北寡妇特级毛片免费| 国产人成777在线视频直播| 国产99久久精品一区二区| 91狠狠爱| 野花社区视频在线观看| 国产成人综合高清在线观看| 亚洲人成日韩中文字幕不卡| 黄网站色视频免费观看| 午夜精品福利一区二区三| 精品一区二区免费不卡| 自拍偷拍午夜福利视频| 色人妻中文字幕| 不卡的在线视频免费观看| 日本特黄特色aaa大片免费欧| 人妻夜夜爽天天爽三区麻豆av| 国产91色在线|亚洲| 骚虎在线永久视频免费观看| 久久婷婷激情亚洲综合色| 尤物精品国产福利网站| 亚洲婷婷综合色高清在线| 久久综合老鸭窝色综合久久| 久久精品国产www456c0m| 男人的天堂av东京| 在线激情天天干| 国产女主播精品一区二区三区 | 日本高清www片久久| 国产传媒| 国产爆乳无码一区二区麻豆| 99热这里只有精品免费播放| 亚洲а∨天堂久久精品2021| 色综合久久中文综合久久激情| 中文人妻无码一区二区三区信息| 亚洲综合久久久| 中文字幕日韩高清一区| 蜜桃视频一区二区在线看| 亚洲精品无码成人aaa片| 蜜臀91精品高清国产福利|